抽象的な

Development and validation of RP-HPLC method for estimation of felodipine in rat plasma

Minal Raghunath Narkhede, Bhanudas Shankar Kuchekar, Jitendra Yadav Nehete


An attempt has been made to develop a simple, precise, sensitive, reproducible and rapid for estimation of felodipine in rat plasma by reverse phase HPLC. Chromatographic separation was achieved on a Spherisorb (250mmï‚´4.6mm, 5 ìm) ODS column using mobile phase (methanol and water) in the ratio 80:20%v/v at a flowrate of 0.9ml/min. Thewavelength of detection was 260 nm. The proposed chromatographic method gave good resolution of the drug in plasma. Felodipine eluted at retention time of 9.94 min. The linearity of themethod was established in the range 50 ng - 150 ng/ mlwith a correlation coefficient of 0.9943 The limit of detection of felodipine was 25 ng/ml and limit of quantification was 50 ng/ml. Excellent precision was evident with a coefficient of variance less than 15%. The developed HPLC method was found to be linear, precise, accurate and reproducible indicatingmethod may be used for the quantitative estimation of felodipine in blood samples.


インデックス付き

  • キャス
  • Google スカラー
  • Jゲートを開く
  • 中国国家知識基盤 (CNKI)
  • サイテファクター
  • コスモスIF
  • 電子ジャーナルライブラリ
  • 研究ジャーナル索引作成ディレクトリ (DRJI)
  • 秘密検索エンジン研究所
  • ICMJE

もっと見る

ジャーナルISSN

ジャーナル h-インデックス

Flyer

オープンアクセスジャーナル