抽象的な

Simultaneous RP-HPLC determination of camylofin dihydrochloride in pharmaceutical preparations

P.S.Barde, A.Y.Desai, Shikha M.N.Roy, V.V.Vaidya


A simple, fast and precise reversed phase high performance liquid chromatographic method is developed for the simultaneous determination of camylofin Dihydrochloride using methyl paraben as an internal standard. Chromatographic separation of these two drugs was performed on a waters symmetry C18 column (250mm  4.6 mm, 5m) as stationary phase with a mobile phase comprising of 0.05%trifluoro acetic acid in water and 0.05% trifluoro acetic acid in acetonitrile (40:60 v/v), at a flowrate of 0.7mLmin-1 and UV detection at 220 nm. The Retention time of Camylofin Dihydrochloride and Methyl paraben were 3.10 min and 4.77 min respectively. The proposed method was validated for linearity, accuracy, precision, LOD, LOQ. Linearity, accuracy and precisionwere found to be acceptable over the ranges of 250-750-g mL-1 for camylofin Dihydrochloride. It can be conveniently adopted for routine quality control analysis.


インデックス付き

  • キャス
  • Google スカラー
  • Jゲートを開く
  • 中国国家知識基盤 (CNKI)
  • サイテファクター
  • コスモスIF
  • 電子ジャーナルライブラリ
  • 研究ジャーナル索引作成ディレクトリ (DRJI)
  • 秘密検索エンジン研究所
  • ICMJE

もっと見る

ジャーナルISSN

ジャーナル h-インデックス

Flyer

オープンアクセスジャーナル